Platforms and vendors
- Ignition
- SQL databases
- ISA-95
- B2MML
- ERP integration
- Rockwell

Metromotion Controls helps mid-size Australian food and beverage manufacturers work out which manufacturing execution system (MES) functions they will actually use, then builds those functions on their existing SCADA and SQL data, or scopes an enterprise MES where the gap is real.
Enterprise MES is built for businesses with many sites, complex scheduling and regulated electronic batch records. A mid-size food plant usually needs a handful of MES functions done well: know what is being made on each line, record what went into it, attribute downtime to the order, and hand the results back to ERP. We map the functions you need against the ISA-95 and MESA models, check what your SCADA and ERP already cover, and build only the gap.
The MESA model lists a long set of MES functions, and enterprise products implement most of them. In a single-site food plant with a few lines, the functions that get used every day are a much shorter list. These are the ones worth building first, because each one removes manual recording or re-keying that someone on site is doing today.
These functions are not unimportant. They are the ones most often bought early and used late, and deferring them keeps the first stage small enough to deliver and adopt. Each can be added once the core records are trusted.
For many mid-size plants the practical path is an MES-lite: the core functions above built on the SCADA platform and SQL database the site already runs or is adopting, with data models that follow ISA-95 so they can grow. Ignition suits this well because data collection, storage, screens and reporting share one platform and one open database, and MES modules can be added where they fit. An enterprise MES is the better answer when the requirements are genuinely enterprise-sized.
An MES consultant can map functions and write a requirements document. The MES still has to be built on the signals the control system produces, and the team that programmed that control system already knows which signals are sound and which need work. Metromotion Controls scopes MES functions and builds them on the same PLC and SCADA layer we program and support, so the MES record can be traced back to the logic that created it without a handover between two firms.
An MES sits between the line and ERP, so its value depends on a clean handshake in both directions: orders and recipes released down, and output, consumption, scrap and batch results posted back. We design that boundary on the ISA-95 object models, with transaction rules for backflush timing, partial completions, duplicates and communication loss agreed before any code is written. The detail is on the ERP and SAP integration page.
We stage MES work so each step is in daily use before the next begins. That keeps the investment tied to results the plant can see and avoids a long project that only pays off at the end.
For many single-site food plants with a limited SKU range, a well-structured SCADA and SQL data layer with orders from ERP covers the need. A dedicated MES earns its cost when recipe and version management, lot genealogy, scheduling across shared equipment or electronic batch records exceed what SCADA and ERP handle cleanly.
MES-lite is a practical term for building only the MES functions a plant uses, usually order tracking, downtime by order, lot records and ERP posting, on the existing SCADA platform and database instead of buying a full enterprise MES.
Yes. Ignition combines data collection, SQL storage, screens and reporting on one platform, and MES modules can be added where they fit. We are an Ignition Gold Certified System Integrator and have delivered Ignition with integrated database storage on production-critical systems such as the McCormick CIP migration.
Through a defined interface that releases orders to the plant and posts results back, ideally following the ISA-95 object models or B2MML. We avoid point-to-point database links that break when either system is upgraded.
With OEE and production monitoring from the PLCs on one line. It produces useful results quickly and builds the signal layer every later MES function depends on.
OEE, reports, quality, CIP, maintenance and energy data from the team that builds and programs the lines.
Live OEE, line status and stop reasons read directly from the PLCs on food and beverage lines.
Live line status, actual rates, stops and CIP in front of the scheduler, for re-planning in real time.
Orders down to the line and counts, consumption, scrap and batch results back to ERPs such as SAP and Pronto Xi.
The ISA-95 levels and the Purdue model explained on a food line, with where each piece of context lives.
Ignition Gold Certified System Integrator for Ignition SCADA, historian, reporting and MES functions.
Connect OEM equipment, production lines, line controls, data systems and site standards into one operating environment.
Automation, traceability, CIP, SCADA and production data for Australian food and beverage plants.
Controls for yoghurt and cheese plants, milk receival, pasteurisation, CIP and production reporting.
CIP automation and Ignition platform work for factory automation upgrades.
OEE and downtime reporting from PLC states, with shift and weekly management reports for an Australian yoghurt plant.
Automated inventory tracking integrated with production controls for real-time stock visibility and traceability.
The ISA-95 levels, the SCADA-to-MES boundary, production tracking and genealogy, B2MML and ERP integration for food manufacturers.
The unified namespace, MQTT and Sparkplug, OPC UA, historian contextualisation and ISA-95 alignment for a single source of plant truth.
OEE meaning and calculation under ISO 22400-2, with a worked two-SKU example and the booking rules that move the figure.
McCormick is one of the world's largest spice and flavouring manufacturers, with production facilities across Australia. When the team needed to migrate a critical Clean-In-Place system to a modern, maintainable platform, Metromotion Controls delivered a full migration to Ignition SCADA with integrated database, multi-terminal operator access, and a distributed control architecture spanning the facility. CIP systems are production-critical in any flavouring or seasoning environment, and the migration was planned and executed to maintain production continuity throughout.
Building on the greenfield automation delivered at Chobani's Australian facility, Metromotion Controls was engaged to develop an OEE data platform that gave the operations team structured visibility of line performance, availability losses, and production output. The project connected existing PLC infrastructure to a centralised reporting environment, establishing consistent downtime reason codes, shift-level OEE calculation, and management dashboards aligned to how the site teams already ran daily reviews.
Tibaldi needed better stock visibility as production volumes increased and manual stock tracking struggled to keep pace with rising throughput. Metromotion Controls implemented automated inventory management integrated with the existing production controls, taking stock movements directly from PLC events into a SQL database rather than relying on manual entry. This kept the inventory record in step with what the line was actually doing, reducing manual entry and improving stock traceability as throughput grew.
Factory data, OEE, reports, quality, CIP, maintenance and energy from the team that builds and programs the lines.
Live line status, actual rates, stops and CIP fed to the schedule, with adherence and forecast finish times, so schedulers can re-plan during the shift.
Production orders and recipes down to the line, and counts, consumption, scrap and batch results back to ERP, on an ISA-95 model with clear transaction rules.
Ignition SCADA, historian, reporting and MES functions designed, built and supported by an Ignition Gold Certified System Integrator in Melbourne.
Speak directly with an engineer about scope, timing and technical constraints.